Authors
Citation
L. Poirier, An evaluation of an air-supplied blouse and an air hood, AM IND HYG, 60(1), 1999, pp. 116-119
Citations number
5
Categorie Soggetti
Environment/Ecology
Journal title
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL
ISSN journal
00028894 → ACNP
Volume
60
Issue
1
Year of publication
1999
Pages
116 - 119
Database
ISI
SICI code
0002-8894(199901/02)60:1<116:AEOAAB>2.0.ZU;2-2
Abstract
Fit factor studies for an air-supplied blouse (blouse) and an air hood resp irator (air hood) were conducted by Lawrence Livermore National Laboratory. Nine test subjects were used to test the blouse. Three subjects were used to test the air hood. Exercises conducted in the test chamber included touc hing toes, raising both arms overhead, squatting, twisting at the torso whi le holding a rod, and running in place, Both the air hood and blouse were t ested with 8 ft(3)/min air supply. Both respirators were worn in a test cha mber. The blouse provided a fit factor of greater than 40,000. The air hood , for nearly all tests, also provided a fit factor greater than 40,000 when worn correctly. Fit factors were also measured for improperly worn air hoo ds.