At. Jackson et al., Utilising time-lag focusing ultraviolet-matrix-assisted laser desorption/ionisation mass spectrometry for the end group analysis of synthetic polymers, ANALUSIS, 26(10), 1998, pp. M31-M35
Time-lag focusing matrix-assisted laser desorption/ionisation-mass spectrom
etry (MALDI-MS) has been employed to analyse synthetic polymers with averag
e molecular weights between approximately 3500 and 12500 Da. Spectra are sh
own that demonstrate the improvement in resolution and sensitivity when tim
e-lag focusing is sued instead of prompt extraction techniques. A resolutio
n of almost 9000 (FWHM) was obtained, in the reflectron mode of operation,
for a poly(methyl methacrylate) PMMA) sample with a relatively narrow dispe
rsion. The data for PMMA polymers of industrial relevance easily enables th
e differentiation of many end groups as a consequence of the improved signa
l-to-noise and good mass accuracy when time-lag focusing is employed.