A transjugular central venous catheter was inadvertently sutured to the wal
l of the right atrium in a 63-year-old female during coronary bypass surger
y. Using two nitinol Goose Neck snares via a transfemoral and a transjugula
r approach the catheter was severed into two pieces and retrieved percutane
ously.