Rapid testing of microbial surface contamination on veal carcasses using ATP bioluminescence

Citation
E. Zwartkruis et al., Rapid testing of microbial surface contamination on veal carcasses using ATP bioluminescence, FLEISCHWIRT, 79(1), 1999, pp. 101-103
Citations number
7
Categorie Soggetti
Food Science/Nutrition
Journal title
FLEISCHWIRTSCHAFT
ISSN journal
0015363X → ACNP
Volume
79
Issue
1
Year of publication
1999
Pages
101 - 103
Database
ISI
SICI code
0015-363X(1999)79:1<101:RTOMSC>2.0.ZU;2-Y
Abstract
This article describes a non-destructive method to screen the microbial lev el on meat carcasses within 10 min. The method consists of the concentratio n of the bacteria-suspension by filtration and then measuring the level of microbial ATP on the filter using the bioluminescence method. The procedure excludes free ATP and ATP from somatic cells and gives a result in Relativ e Light Units (RLU), corresponding with the number of microorganisms on the surface of the carcass. At a German meat company 66 veal carcasses have be en tested. This study produced a correlation between the plate count method and the bioluminescent method of r=0.91. The detection limit was 500 CFU/c m(2).