Prevention of adhesion formation with use of sodium hyaluronate-based bioresorbable membrane in a rat model of ventral hernia repair with polypropylene mesh - A randomized, controlled study
Gd. Hooker et al., Prevention of adhesion formation with use of sodium hyaluronate-based bioresorbable membrane in a rat model of ventral hernia repair with polypropylene mesh - A randomized, controlled study, SURGERY, 125(2), 1999, pp. 211-216
Background. There is a high incidence of adhesions after. ventral hernia re
pair with polypropylene mesh. Hyaluronic acid (HA)-based membrane has been
shown to reduce the incidence of adhesions in the absence of prosthetic mes
h. The purpose of this study was to determine the effect of HA membrane on
the quantity and grade of adhesions and its effect on strength of repair af
ter abdominal wall repair with polypropylene mesh.
Methods, In 61 rats a full-thickness abdominal wall defect (excluding skin)
was created, and a section of small bowel was abraded. The animals were ra
ndomized receiving either HA membrane to cover the viscera or no membrane.
The fascial defect was repaired with polypropylene mesh. Equal numbers of a
nimals from each group were killed at 4 weeks and 8 weeks after surgery. Ad
hesion severity and percentage of mesh surface covered with adhesions were
estimated. Tensile strength between mesh and muscle from each animal was me
asured. Sections of the mesh-muscle interface were examined histologically
and measured for thickness and graded for inflammation and fibrosis.
Results, Fifty-five animals survived until the end point Animals in the HA
membrane group had a significant reduction in (1) grade of adhesions betwee
n small bowel and mesh at 4 weeks (P =.009) and 8 weeks (P =.000001), (2) g
rade of adhesions between colon and mesh at 8 weeks (P =.00003), and (3) pe
rcentage of mesh covered with adhesions at 4 weeks (P =.01) and 8 weeks (P
=. 0000002). There was no difference between the 2 groups in tensile streng
th of the repairs, tissue thickness, degree of inflammation, or degree of f
ibrosis.
Conclusions, HA membrane reduces the quantity and grade of adhesions of bot
h snail and large bowel, to polypropylene mesh in a rat model of ventral he
rnia repair; without compromising strength of the repair.