A calibration of the ROSAT HRI UV leak

Citation
Tw. Berghofer et al., A calibration of the ROSAT HRI UV leak, ASTRON ASTR, 342(1), 1999, pp. L17-L20
Citations number
17
Categorie Soggetti
Space Sciences
Journal title
ASTRONOMY AND ASTROPHYSICS
ISSN journal
00046361 → ACNP
Volume
342
Issue
1
Year of publication
1999
Pages
L17 - L20
Database
ISI
SICI code
0004-6361(199902)342:1<L17:ACOTRH>2.0.ZU;2-1
Abstract
The purpose of this paper is to present a detailed investigation of the Ult raviolet and visible sensitivity of the high-resolution imager (HRI) onboar d the ROSAT X-ray satellite. We provide observational evidence that a recen tly published model (Zombeck et al. 1997) of the out-of-band quantum effici ency of the HRI overpredicts the detector response longward of approximatel y 4000 Angstrom. The contamination of the HRI is limited to the UV bandpass below approximately 4000 Angstrom. Based on the optical properties of our target stars, our ROSAT HRI and PSPC observations, and UV fluxes measured w ith the TD1 satellite, we provide an accurate calibration for the UV leak f lux and present formulae to estimate UV leak count rates based on UV (1965 Angstrom) fluxes or stellar U magnitudes.