Sc. Mantell et Ej. Linstrom, Nondestructive evaluation of interlaminar bonding for in situ consolidation of polymer composites, J COMPOS MA, 33(2), 1999, pp. 124-157
A sensor for detecting poor interlaminar bonding between a topmost ply and
composite substrate was developed and validated. The sensor was designed fo
r the specific application of real time process control for in situ consoli
dation processes, such as thermoplastic tow placement. The sensor design co
nsists of two piezoelectric transducers oriented in a pitch catch arrangeme
nt. The transmitting transducer is angled so as to produce surface waves in
the composite panel. These waves interact with defects at the top ply/subs
trate interface. The received signal was analyzed for wave speed, attenuati
on and energy dissipation (power spectral density). Experimental validation
of the sensor is presented. Several composite panels were made under vario
us manufacturing conditions so as to create poor interlaminar bonding at th
e topmost ply. Interlaminar bonding was then evaluated by destructive and n
ondestructive measures. There was good agreement between the destructive an
d nondestructive measures of top ply bond strength.