Alternative sample sizes for verification dose experiments and dose audits

Citation
Wa. Taylor et Jm. Hansen, Alternative sample sizes for verification dose experiments and dose audits, RADIAT PH C, 54(1), 1999, pp. 65-75
Citations number
6
Categorie Soggetti
Physics
Journal title
RADIATION PHYSICS AND CHEMISTRY
ISSN journal
0969806X → ACNP
Volume
54
Issue
1
Year of publication
1999
Pages
65 - 75
Database
ISI
SICI code
0969-806X(199901)54:1<65:ASSFVD>2.0.ZU;2-T
Abstract
ISO 11137 (1995), "Sterilization of Health Care Products-Requirements for V alidation and Routine Control-Radiation Sterilization", provides sampling p lans :For performing initial verification dose experiments and quarterly do se audits. Alternative sampling plans are presented which provide equivalen t protection. These sampling plans can significantly reduce the cost of tes ting. These alternative sampling plans have been included in a draft ISO Te chnical Report (type 2). This paper examines the rational behind the proposed alternative sampling p lans. The protection provided by the current verification and audit samplin g plans is first examined. Then methods for identifying equivalent plans ar e highlighted. Finally, methods for comparing the cost associated with the different plans are provided. This paper includes additional guidance for s electing between the original and alternative sampling plans not included i n the technical report. (C) 1999 Elsevier Science Ltd. All rights reserved.