In cooperation with Alfa Laval Thermal AB Company in Sweden, a steam conden
sation test rig of a plate heal exchanger (PHE) was set up. The heat transf
er and pressure drop characteristics of two kinds of typical operation cond
ition in a PHE were obtained: complete condensation and partial condensatio
n. This article introduces the test rig, various sensors, and the data acqu
isition system used in the measurements. The process of steam condensation
in a PHE is analyzed in detail. The two-phase frictional pressure drop alon
g this wavy channel was obtained from the measured steam condensation press
ure drop. The Lockhart-Martinelli model was extended to predict the pressur
e drop of steam condensation in a PHE and was verified by the experimental
results. Based an the data processing of 109 experimental points, a correla
tion of frictional pressure drop of steam condensation in a PHE is suggeste
d. This correlation is recommended for calculation of the steam condensatio
n pressure drop in a PHE.