Performance analysis of fast reclosing transients in induction motors

Citation
J. Faiz et al., Performance analysis of fast reclosing transients in induction motors, IEEE EN CON, 14(1), 1999, pp. 101-107
Citations number
8
Categorie Soggetti
Environmental Engineering & Energy
Journal title
IEEE TRANSACTIONS ON ENERGY CONVERSION
ISSN journal
08858969 → ACNP
Volume
14
Issue
1
Year of publication
1999
Pages
101 - 107
Database
ISI
SICI code
0885-8969(199903)14:1<101:PAOFRT>2.0.ZU;2-7
Abstract
Induction motors are used extensively in the heavy industry. For these load s, this often requires reclosing on the motor before it reaches zero speed. However, if the supply voltage is applied before the motor reaches zero sp eed, the motor can be damaged due to excessive current and torque transient s. This paper presents a performance analysis of fast reclosing transients in induction motors. It is shown that the optimum time instant for reclosin g depends upon the supply voltage and load parameters. The results indicate that the maximum absolute value of instantaneous torque occurs in the firs t cycle and for every time cycle of supply voltage. In fact, there are at l east one positive peak and one negative peak for the torque.