A. Lalande et al., Automatic detection of left ventricular contours from cardiac cine magnetic resonance imaging using fuzzy logic, INV RADIOL, 34(3), 1999, pp. 211-217
Citations number
18
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
RATIONALE AND OBJECTIVES. Gated cardiac cine magnetic resonance imaging pro
vides accurate dynamic data of the left ventricular function, However, the
manual extraction of important physiologic parameters such as myocardium wa
ll thickness and left ventricular volumes is invariably time consuming and
subjective, To reduce the variability and time constraints inherent in obse
rver contour tracing, the authors developed an automatic left ventricle con
tour-detection method.
METHODS. The purpose was to apply fuzzy logic-based automatic contour detec
tion to identification of endocardial and epicardial borders in short-axis
magnetic resonance images, The automatic contouring was compared with manua
l tracing using the calculated ejection fraction as the comparison criterio
n.
RESULTS. A good correlation was found between the two approaches (r(2) = 0.
98).
CONCLUSIONS. The ejection fraction can be obtained using this automatic con
touring method.