The effects of the volume fraction of SiC particulate reinforcements and th
e concentration of chloride ions in solution on the localized corrosion cha
racteristics of SiCp/2024 AI metal matrix composites (MMC) were investigate
d. A scanning micro reference electrode (SMRE) technique was employed to st
udy the dynamic process of pitting initiation and development on the surfac
e of the composites at open-circuit potential. Potentiodynamic polarization
s were performed to characterize the electrochemical behavior of the MMCs.
The morphology of the localized attack on the MMC sample after corrosion te
sts were examined by scanning electron microscopy (SEM). The results of ele
ctrochemical measurement showed that the composites were less resistant to
pit initiation than the corresponding unreinforced metrix alloy. Increase i
n the volume fraction of SiCp reinforcement in the SiCp/2024 Al composites
resulted in a significant decrease of pitting potential. In situ potential
mapping of active centers on the surfaces of the composites revealed that l
ocal breakdown of passivity and initiation of micro pitting corrosion could
take place even at an open-circuit potential which was more negative than
the pitting potential, and the number of active centers on the surfaces of
the composites increased as the volume fraction of SiC particulates in MMCs
increased. Micro-structural analysis indicated that pitting attack on the
composites mainly occurred at SiCp-Al interfaces or inclusions-Al interface
s. (C) 1998 Kluwer Academic Publishers.