A new measuring device for measuring valve lift

Authors
Citation
M. Marcic, A new measuring device for measuring valve lift, REV SCI INS, 70(3), 1999, pp. 1885-1888
Citations number
5
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN journal
00346748 → ACNP
Volume
70
Issue
3
Year of publication
1999
Pages
1885 - 1888
Database
ISI
SICI code
0034-6748(199903)70:3<1885:ANMDFM>2.0.ZU;2-0
Abstract
The injection system is the main unit of diesel engines, having a major imp act on proper operation of the engines. The delivery valve as an important element of the injection system assures its smooth functioning. In order to learn as much as possible about the movement of the delivery valve during the operation of the injection system, an inductive displacement transducer has been designed. The results of the measurements clearly indicate that t he movements of the delivery valve are in agreement with the other measured parameters of the injection and that the proposed method for measuring the delivery valve lift can be successfully used with certain types of deliver y valves. (C) 1999 American Institute of Physics. [S0034-6748(99)03803-4].