Diagnostics of an argon arcjet plume with a diode laser

Citation
Fy. Zhang et al., Diagnostics of an argon arcjet plume with a diode laser, APPL OPTICS, 38(9), 1999, pp. 1814-1822
Citations number
30
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Optics & Acoustics
Journal title
APPLIED OPTICS
ISSN journal
00036935 → ACNP
Volume
38
Issue
9
Year of publication
1999
Pages
1814 - 1822
Database
ISI
SICI code
0003-6935(19990320)38:9<1814:DOAAAP>2.0.ZU;2-3
Abstract
The diode-laser absorption technique was applied for simultaneous velocity and temperature measurements of an argon plume exhausted by an arcjet. The Ar I absorption line at 811.531 nm was taken as the center absorption line. The velocity and the temperature were derived from the Doppler shift in th e absorption profiles and the full width at half-maximum of the plume absor ption profile, respectively. From the measured plume velocity and temperatu re, the total enthalpy of the exhausted plume, the thrust efficiency, and t he thermal efficiency of the arcjet were derived, and the performance of th e arcjet was examined. The results are demonstrated to agree with results d erived by other methods, and the technique can be applied to the measuremen t of other arcjet systems without much modification. (C) 1999 Optical Socie ty of America.