Control of a three-phase PWM rectifier using estimated ac-side and dc-sidevoltages

Citation
T. Ohnuki et al., Control of a three-phase PWM rectifier using estimated ac-side and dc-sidevoltages, IEEE POW E, 14(2), 1999, pp. 222-226
Citations number
6
Categorie Soggetti
Eletrical & Eletronics Engineeing
Journal title
IEEE TRANSACTIONS ON POWER ELECTRONICS
ISSN journal
08858993 → ACNP
Volume
14
Issue
2
Year of publication
1999
Pages
222 - 226
Database
ISI
SICI code
0885-8993(199903)14:2<222:COATPR>2.0.ZU;2-K
Abstract
A new control method of a pulsewidth modulation (PWM) rectifier without mea suring ac- and de-side voltages is proposed. rls information about these vo ltages is necessary for the controller, all required voltage values are est imated from the measured line currents and the calculated values of the inp ut reactor voltage during switching of the rectifier circuit. The input rea ctor voltage can be obtained by using a differentiator that produces the de rivative of the Line current or by detecting the voltage induced in a secon dary winding wound on the input reactor, The secondary winding creates the electric isolation between the main circuit and the controller, The propose d method is verified bg experiment. This paper describes the estimation met hod, gives the configuration of the controller, and discusses steady-state and transient performances of the rectifier.