X. Luo et Ddl. Chung, A comparative study of silver-epoxy and tin-lead solder in their joints with copper, through mechanical and electrical measurements during debonding, J MATER SCI, 34(2), 1999, pp. 273-276
A comparative study of silver-epoxy and tin-lead solder in their joints wit
h copper was made through simultaneous mechanical and electrical measuremen
ts during debonding. Silver-epoxy joints to copper abruptly increased in co
ntact electrical resistivity upon completion of shear debonding, whereas ti
n-lead soldered joints to copper did not, due to the higher ductility of so
lder compared to silver-epoxy. The contact resistivity before debonding was
higher for silver-epoxy than solder. Cleansing of the copper surface was e
ssential for silver-epoxy, but not for solder. Acetone washing of copper su
rface helped silver-epoxy joints, but not soldered joints. Acid washing hel
ped soldered joints more than acetone washing, but helped silver-epoxy join
ts to the same extent as acetone washing. (C) 1999 Kluwer Academic Publishe
rs.