Experimental investigation on the efficiency of a high side weir overflow

Citation
G. Luyckx et al., Experimental investigation on the efficiency of a high side weir overflow, WATER SCI T, 39(2), 1999, pp. 61-68
Citations number
7
Categorie Soggetti
Environment/Ecology
Journal title
WATER SCIENCE AND TECHNOLOGY
ISSN journal
02731223 → ACNP
Volume
39
Issue
2
Year of publication
1999
Pages
61 - 68
Database
ISI
SICI code
0273-1223(1999)39:2<61:EIOTEO>2.0.ZU;2-L
Abstract
Most of the overflow structures in Flanders are 'high side weir overflows'. For the design of these structures British guidelines are used. However, t he design conditions for sewer systems in the U.K. differ from the Flemish design conditions. In Flanders, pressurised flow is in common use in the pi pes of the sewer system. That is why tests have been carried out on a scale model of a high side weir overflow. The optimal dimensions are determined, using different model sediments. Also efficiency relationships have been d etermined. For a particular chamber geometry and particular flow conditions , the efficiency of a certain sediment fraction is only determined by the s ettling velocity of this fraction. (C) 1999 IAWQ Published by Elsevier Scie nce Ltd. All rights reserved.