Combined use of Orgaran and Reopro during coronary angioplasty in patientsunable to receive heparin

Citation
Wj. Cantor et al., Combined use of Orgaran and Reopro during coronary angioplasty in patientsunable to receive heparin, CATHET C IN, 46(3), 1999, pp. 352-355
Citations number
21
Categorie Soggetti
Cardiovascular & Respiratory Systems
Journal title
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
ISSN journal
15221946 → ACNP
Volume
46
Issue
3
Year of publication
1999
Pages
352 - 355
Database
ISI
SICI code
1522-1946(199903)46:3<352:CUOOAR>2.0.ZU;2-F
Abstract
Orgaran, a heparinoid, has been used successfully in patients with heparin- Induced thrombocytopenia. We report three cases in which Orgaran was combin ed with the glycoprotein Ilb/IIa receptor antagonist Reopro during coronary angioplasty. Orgaran was given as a single intravenous bolus of 1500 anti- factor Xa units. No ischemic or hemorrhagic complications occurred during o r following the procedure. (C) 1999 Wiley-Liss, Inc.