Comparison of corrosion protection provided by a non-volatile organic compound epoxy and a marine epoxy primer

Citation
Mw. Kendig et al., Comparison of corrosion protection provided by a non-volatile organic compound epoxy and a marine epoxy primer, CORROSION, 55(3), 1999, pp. 222-228
Citations number
7
Categorie Soggetti
Material Science & Engineering
Journal title
CORROSION
ISSN journal
00109312 → ACNP
Volume
55
Issue
3
Year of publication
1999
Pages
222 - 228
Database
ISI
SICI code
0010-9312(199903)55:3<222:COCPPB>2.0.ZU;2-R
Abstract
An epoxy resin formulation completely free of organic solvent was applied t o carbon steel coupons using supercritical carbon dioxide (CO2) as the vola tile solvent. Sleet coupons coated in this manner were compared to coupons coated with a standard military specification marine primer (MIL-P-24441) d uring exposure to aerated 0.5 nrl sodium chloride (NaCl). The solvent-free coating protected the steel from corrosion in this environment as well, if not better than, the solvent-based primer.