Variation method for inverse treatment planning

Citation
Y. Liu et al., Variation method for inverse treatment planning, MED PHYS, 26(3), 1999, pp. 356-363
Citations number
17
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Journal title
MEDICAL PHYSICS
ISSN journal
00942405 → ACNP
Volume
26
Issue
3
Year of publication
1999
Pages
356 - 363
Database
ISI
SICI code
0094-2405(199903)26:3<356:VMFITP>2.0.ZU;2-H
Abstract
A new inverse planning method based on the theory of variation is developed for the computation of beam intensities that produce highly conformal dose distributions to the target volume that have an arbitrary complex geometry . It is shown that the objective function defined for the optimization of e xternal beam intensities has a unique minimum. A corresponding algorithm is then designed to generate a sequence of intensity functions that converge to the minimum. The algorithm is applied to a test geometry where the targe t volume has concavity and then are adjacent critical organs. The cumulativ e dose-area histogram, the two-dimensional version of the cumulative dose-v olume histogram, is used to evaluate the outcomes of this new inverse plann ing method. The results show that this method creates a group of intensity- modulated external beams that produce a dose distribution consistent with t he given dose prescription. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01503-5].