RAPID SEMIQUANTITATIVE DETERMINATION OF IRON IN POTABLE WATER USING AN INDICATOR PAPER

Citation
Rp. Pantaler et al., RAPID SEMIQUANTITATIVE DETERMINATION OF IRON IN POTABLE WATER USING AN INDICATOR PAPER, Journal of analytical chemistry, 52(4), 1997, pp. 341-343
Citations number
12
Categorie Soggetti
Chemistry Analytical
ISSN journal
10619348
Volume
52
Issue
4
Year of publication
1997
Pages
341 - 343
Database
ISI
SICI code
1061-9348(1997)52:4<341:RSDOII>2.0.ZU;2-C
Abstract
A rapid test procedure is proposed for the detection and semiquantitat ive determination of total iron and weakly bound iron species with the use of an indicator paper. Phenylfluorone was used as the indicator. The detection limit of iron (II, III) was found to be 0.2 mg/L at a fi ducial probability of 0.95.