M. Gasparini et al., Congestive heart failure induced by recipient atrial tachycardia conductedto the donor atrium after orthotopic heart transplantation: Complete regression after successful radiofrequency ablation, J CARD ELEC, 10(3), 1999, pp. 399-404
Citations number
15
Categorie Soggetti
Cardiovascular & Respiratory Systems","Cardiovascular & Hematology Research
Graft Failure and Recipient Atrial Tachycardia. We describe the case of a 3
0-year-old female patient who developed an interatrial tachycardia from the
recipient to the donor atrium associated with signs of congestive heart fa
ilure 5 years after orthotopic heart transplantation. The patient underwent
catheter mapping followed by successful radiofrequency (RF) ablation at th
e site of the presumed electrical connection between the recipient and the
donor atria, through the interatrial surgical suture line, with stable reco
very of sinus rhythm and disappearance of signs of left ventricular dysfunc
tion, RF catheter ablation is confirmed to be feasible and safe in the trea
tment of heart transplant patients even in the presence of rare forms of ar
rhythmias, thus offering a cure for tachycardia to these patients.