As an imaging plate neutron detector (IP-ND) has been available for thermal
neutron radiography (TNR) which has high resolution, high sensitivity and
wide range, some basic characteristics of the IP-ND system were measured at
the E-2 facility of the KUR. After basic performances of the IP were studi
ed, images with high quality were obtained at a neutron fluence of 2 to 7 x
10(8) n cm(-2). It was found that the IP-ND system with Gd2O3 as a neutron
converter material has a higher sensitivity to gamma-ray than that of a co
nventional film method. As a successful example, clear radiographs of the B
at view for the fuel side plates with boron burnable poison were obtained.
An application of the IP-ND system to neutron radiography (NR) is presented
in this paper. (C) 1999 Elsevier Science B.V. All rights reserved.