M. Pettersson et al., ANALYSIS AND VALIDATION OF A SIMPLIFIED MODEL OF A WET FLUE-GAS CLEANING SYSTEM, Journal of process control, 8(1), 1998, pp. 69-76
Citations number
12
Categorie Soggetti
Engineering, Chemical","Robotics & Automatic Control
Combustion of waste produces large variations in flue gas composition.
These variations lead to dynamic effects in the emission control syst
em. Variations in scrubber liquid pH is a typical effect, influencing
the absorption of pollutants. A dynamic model for a wet system for SO2
removal was built using an existing plant in Hobro, Denmark as a mode
l system. An experimental validation showed that the model has a good
agreement with operating data. There was one important limitation to m
odel performance. The absorption of HCl were not modelled and the expe
riments proved this to be an important process characteristic. A linea
r analysis of the model showed that the process is approximately a fir
st order system. The process gain is however changing with changing ch
emical composition of the scrubber liquid, which makes a robust contro
ller design hard to achieve. Some concluding remarks are made on plant
and control system design. (C) 1997 Elsevier Science Ltd.