B. Larsen et al., ENHANCED SELECTIVITY IN THE ANALYSIS OF CHLOROBIPHENYLS ON A CARBORANE PHENYLMETHYLSILOXANE COPOLYMER GAS-CHROMATOGRAPHY PHASE (HT-8), Journal of chromatography, 708(1), 1995, pp. 115-129
Citations number
26
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
The congener specific analysis of polychlorinated biphenyls (PCBs) on
a new chemically bonded stationary GC phase, HT-8 (1,7-dicarba-closo-d
odecarborane phenylmethyl siloxane) is investigated. The incorporation
of carborane in the polysiloxane backbone enhances selectivity and te
mperature stability of the phase. On a 60 m X 0.25 mm I.D. fused-silic
a column coated with 0.25 mu m HT-8, a total of 106 congeners in Arocl
or mixtures elute as separated peaks. By the use of mass spectrometric
detection 138 congeners can be analysed without interference from coe
luting PCBs. In literature, no other GC phase has been reported with s
uch a high PCB selectivity. An interesting feature of HT-8 is its near
-baseline separation of the critical pair CB138/CB163. Separations for
these congeners on other GC phases are reviewed. The performance of a
thin film (0.15 mu m) version of the HT-8 column with fast temperatur
e programming is tested. It is concluded that congener-specific rapid
screening of seven indicator PCBs (CB28, CB52, CB101, CB118, CB138, CB
153 and CB180) with a total GC run-time of 13 min is feasible with an
accuracy sufficient for most purposes.