NEW CONTACTLESS INDUCTIVE SENSOR FOR THE MEASUREMENT OF CONCENTRATIONOF AN ELECTROLYTIC SOLUTION

Citation
Abm. Ismail et K. Shida, NEW CONTACTLESS INDUCTIVE SENSOR FOR THE MEASUREMENT OF CONCENTRATIONOF AN ELECTROLYTIC SOLUTION, JPN J A P 1, 36(10), 1997, pp. 6558-6561
Citations number
9
Volume
36
Issue
10
Year of publication
1997
Pages
6558 - 6561
Database
ISI
SICI code
Abstract
In this paper an inductive sensor with a new and simple contactless st ructure to determine the concentration of an electrolytic solution is presented. The authors propose a novel idea ol designing the sensing c oil of the sensor so that the magnetic field is focused inside the con ducting liquid, thereby increasing the sensitivity of the sensing coil . By detecting the change in inductance of the sensing coil due to a s olution of known concentrations of a particular electrolyte, a databas e is created, With the help of this database it is possible to estimat e the unknown concentration of an electrolytic solution, It was tested for various concentrations of NaCl and it shows a distinct response f or each concentration.