STENT DEFORMATION AND INTIMAL HYPERPLASIA COMPLICATING TREATMENT OF APOSTCAROTID ENDARTERECTOMY INTIMAL FLAP WITH A PALMAZ STENT

Citation
Sp. Johnson et al., STENT DEFORMATION AND INTIMAL HYPERPLASIA COMPLICATING TREATMENT OF APOSTCAROTID ENDARTERECTOMY INTIMAL FLAP WITH A PALMAZ STENT, Journal of vascular surgery, 25(4), 1997, pp. 764-768
Citations number
28
Categorie Soggetti
Surgery,"Peripheal Vascular Diseas
Journal title
ISSN journal
07415214
Volume
25
Issue
4
Year of publication
1997
Pages
764 - 768
Database
ISI
SICI code
0741-5214(1997)25:4<764:SDAIHC>2.0.ZU;2-N
Abstract
We report a case of common carotid artery Palmaz stent placement for t reatment of an intimal flap after surgical endarterectomy. Despite tec hnical success with an excellent immediate result, a significant steno sis detected by duplex sonographic examination developed at 10 months. This stenosis, the result of stent compression and intimal hyperplasi a, illustrates the previously theoretic risk associated with placement of the balloon-expandable stent in a compressible site such as the ce rvical carotid artery. In addition, we demonstrate that significant in timal hyperplasia may occur after carotid artery stent placement, pote ntially limiting long-term patency.