EFFECT OF TWISTED STRIPS ON HEAT-TRANSFER AND PRESSURE-DROP IN HEAT-EXCHANGERS

Citation
C. Yildiz et al., EFFECT OF TWISTED STRIPS ON HEAT-TRANSFER AND PRESSURE-DROP IN HEAT-EXCHANGERS, Energy conversion and management, 39(3-4), 1998, pp. 331-336
Citations number
16
Categorie Soggetti
Energy & Fuels",Mechanics,Thermodynamics
ISSN journal
01968904
Volume
39
Issue
3-4
Year of publication
1998
Pages
331 - 336
Database
ISI
SICI code
0196-8904(1998)39:3-4<331:EOTSOH>2.0.ZU;2-Z
Abstract
Twisted narrow, thin metallic strips were placed in the inner pipe of a concentric double-pipe heat exchanger. Their effects on heat transfe r and pressure drop were studied for parallel and countercurrent flow. These turbulators were prepared by twisting the strips through certai n angles and designed to touch the inside wall at each step. In the sy stem, hot air was passed through the inner pipe, while cold water was flowing through the annulus. Experiments performed with an empty inner tube confirmed the results with the Dittus-Boelter expression given f or the Nusselt number. It was observed that the Nu number could increa se up to 100% at a cost of about 130% increase in pressure drop for th e tube with twisted strips inside. (C) 1997 Elsevier Science Ltd.