G. Zavattini et al., LINEARITY DISCONTINUITIES IN XE-FILLED X-RAY MICROSTRIP DETECTORS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 401(2-3), 1997, pp. 206-216
A prototype Xe + 10% CH4 microstrip detector was used to study the K-e
dge discontinuity in the pulse-height distribution as a function of th
e energy of incident X-rays, The electronics used was such that a puls
e-shape rejection could be made of K-fluorescence reabsorption in the
detector, The measured jump at the K-edge was (169 +/- 12)eV. It was a
lso seen that K-alpha- and K-beta-decay channels produce different pul
se heights for the same deposited energy. We find that the difference
in energy between the calibration fines of the K-beta 2- and the K-bet
a 1.3-escape peaks is (93+/-12)eV whereas between the K-beta 1.3 and t
he K-alpha-escape peaks' calibration tile energy gal? is (69+/-7)eV.