S. Meigo, MEASUREMENTS OF THE RESPONSE FUNCTION AND THE DETECTION EFFICIENCY OFAN NE213 SCINTILLATOR FOR NEUTRONS BETWEEN 20 AND 65 MEV, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 401(2-3), 1997, pp. 365-378
For neutrons 25, 30 and 65 MeV, the response functions and detection e
fficiencies of an NE213 liquid scintillator were measured. Quasi-monoe
nergetic neutrons produced by the Li-7(p,n(0,1)) reaction were employe
d for the measurement and the absolute flux of incident neutrons was d
etermined within 4% accuracy using a proton recoil telescope. Response
functions and detection efficiencies calculated with the Monte Carlo
codes, CECIL and SCINFUL, were compared with the measured data. Ir was
found that response functions calculated with SCINFUL agreed better w
ith experimental ones than those with CECIL, however, the deuteron lig
ht output used in SCINFUL was too low. The response functions calculat
ed with a revised SCINFUL agreed with the experimental ones quite well
even for the deuteron bump and peak due to the C(n,d(0)) reaction. It
was confirmed that the detection efficiencies calculated with the ori
ginal and the revised SCINFULs agreed with the experimental data withi
n the experimental error, while those with CECIL were about 20% higher
in the energy region above 30 MeV.