DIFFUSIVE CRACK-HEALING BEHAVIOR IN POLYCRYSTALLINE ALUMINA - A COMPARISON BETWEEN MICROWAVE ANNEALING AND CONVENTIONAL ANNEALING

Citation
Ba. Wilson et al., DIFFUSIVE CRACK-HEALING BEHAVIOR IN POLYCRYSTALLINE ALUMINA - A COMPARISON BETWEEN MICROWAVE ANNEALING AND CONVENTIONAL ANNEALING, Materials research bulletin, 32(12), 1997, pp. 1607-1616
Citations number
56
Journal title
ISSN journal
00255408
Volume
32
Issue
12
Year of publication
1997
Pages
1607 - 1616
Database
ISI
SICI code
0025-5408(1997)32:12<1607:DCBIPA>2.0.ZU;2-H
Abstract
Crack-healing experiments via both conventional heating and microwave heating were performed on Vickers-indented specimens of polycrystallin e alumina (Coors ADS-995). For the entire temperature range included i n this experiment (1510-1742 K), the crack-healing rate was enhanced f or microwave heating compared to conventional heating. The microwave c rack-healing data were described well by a diffusive mass transport mo del given by Stevens and Dutton. (C) 1997 Elsevier Science Ltd.