G. Oliveto et Ld. Decanini, REPAIR AND RETROFIT OF A 6 STORY REINFORCED-CONCRETE BUILDING DAMAGEDBY THE EARTHQUAKE IN SOUTH-EAST SICILY ON THE 13TH DECEMBER 1990, Soil dynamics and earthquake engineering, 17(1), 1998, pp. 57-71
This paper presents the studies that led to the seismic retrofitting o
f a six storey reinforced concrete building damaged by the 1990 earthq
uake in south-east Sicily. A seismological study, available geological
information and extensive geotechnical tests led to the definition of
the ultimate design earthquake for the site. A detailed damage survey
and a numerical damage simulation together with available information
on the design and construction history denounced the highly deficient
condition of the building against the design seismic action. After ha
ving established, through a campaign of destructive and non-destructiv
e tests, the main structural characteristics of the materials and of t
he structural elements, joints included, seven different retrofitting
systems are presented and discussed. Finally the recommended solution
is presented in some detail and the methods of analysis and the conduc
ted safety checks are briefly described. (C) 1997 Elsevier Science Ltd
.