Purpose: To evaluate in vitro the dentin and enamel shear bond strengt
h of two adhesive systems that contain acidic primers. Materials and M
ethods: Clearfil Liner Bond 2 (CLB2) and Denthesive II (DTII), contain
ing acid primers were used with (ETCH) and without (NOET) etching. Sco
tchbond Multi-Purpose (SBMP) was utilized as a control. Sixty flat ena
mel and dentin bonding sites were prepared to 600 grit on extracted hu
man molars. Both acidic primer systems were used with (ETCH) and witho
ut etching (NOET) for both enamel and dentin surfaces. The control gro
up used etching only. After applying primer and adhesive, a microfill
composite (Silux Plus) was placed in a 2.5 mm diameter matrix on the t
ooth surface, and polymerized for 40 seconds. All specimens were therm
ocycled 500 times. Shear bond strengths were determined using a Zwick
testing machine. Results: One-way ANOVA revealed significant differenc
es among groups for enamel (P=0.0001) and dentin (P=0.0002). Duncan's
multiple range test (alpha = 0.05) revealed that enamel shear bond str
ength of DTII-ETCH was equal to that of CLB2-NOET and these were signi
ficantly greater than CLB2-ETCH, SBMP and DTII-NOET. For dentin, bond
strengths for CLB2-ETCH and CLB2-NOET were significantly greater than
DTII-NOET.