Porous carbon electrodes containing platinum and platinum-ruthenium ca
talysts are prepared by a rolling technique with polytetrafluoroethyle
ne as a binder. The 5 and 10 wt.% of the catalyst is deposited on a ca
rbon substrate (Vulcan XC-72) by a colloidal dispersion technique. Hal
f-cell polarization studies in 2.50 M H2SO4 electrolyte containing CH3
OH (1.0-3.0 M) have been carried out. The polarization values of elect
rodes containing platinum-ruthenium are lower than that of catalysts c
ontaining platinum only. Porous electrodes containing 2-5.0 mg cm(-2)
of catalyst exhibit a polarization value of less than 300 mV at 100 mA
cm(-2) at 60 degrees C in 2.50 M H2SO4. (C) 1997 Elsevier Science S.A
.