A failure compression test with a standardized procedure for protein g
elation was developed, Using whey protein concentrate, egg white prote
in and soy protein isolate as representative proteins, a highly reprod
ucible procedure for sample preparation and gel testing was developed
after refinements, Gels of varying protein concentrations were prepare
d with 0.1M NaCl at pH 7, Force (N) and strain (Delta h/h) at failure
were the main parameters measured, Variability of results was found du
e to uncontrolled conditions for protein hydration and pH adjustment a
nd air incorporation during hydration, After corrective steps to avoid
potential errors, the procedure was recommended for a routine analysi
s of failure properties of protein gels.