LITHIUM BATTERIES - APPLICATION OF NEUTRON RADIOGRAPHY

Citation
M. Kamata et al., LITHIUM BATTERIES - APPLICATION OF NEUTRON RADIOGRAPHY, Journal of power sources, 68(2), 1997, pp. 459-462
Citations number
9
Journal title
ISSN journal
03787753
Volume
68
Issue
2
Year of publication
1997
Pages
459 - 462
Database
ISI
SICI code
0378-7753(1997)68:2<459:LB-AON>2.0.ZU;2-M
Abstract
Several kinds of primary and secondary commercial lithium batteries, s uch as CR1/3.1H (Fujitsu), CR1220 and BR435 (Panasonic), ML1220 (Sanyo Excel) were investigated using neutron radiography; the variation of the lithium distribution inside these batteries upon discharging (and charging) were clarified by analyzing their visualized images. It was demonstrated that neutron radiography is a potential and useful method , especially in evaluating the reversibility of rechargeable batteries , which have been used under different discharging/ charging condition s. (C) 1997 Elsevier Science S.A.