A HIGH-RESOLUTION, LARGE ACCEPTANCE SCINTILLATION TIME-OF-FLIGHT SPECTROMETER

Citation
P. Grabmayr et al., A HIGH-RESOLUTION, LARGE ACCEPTANCE SCINTILLATION TIME-OF-FLIGHT SPECTROMETER, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 402(1), 1998, pp. 85-94
Citations number
43
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
402
Issue
1
Year of publication
1998
Pages
85 - 94
Database
ISI
SICI code
0168-9002(1998)402:1<85:AHLAST>2.0.ZU;2-V
Abstract
A high-resolution detector array has been developed for the measuremen t of momenta of charged and uncharged particles via the time-of-flight method. This spectrometer represents one detector arm of a system use d to study the photoabsorption mechanisms of (gamma, NN) and (gamma, p i N) reactions. It is comprised of 112 plastic scintillators (NE110) o f dimensions 5 x 20 x 300 cm(3) with a photomultiplier attached to eac h end. A mean time resolution of less than or similar to 400 ps (FWHM) and a position resolution of less than or similar to 6 cm have been a chieved. The modularity and flexibility of the array encouraged its us e in other electron-and photon-induced reaction measurements.