KINETICS IN A EU(III)-HUMIC ACID SYSTEM BY ISOTOPIC EXCHANGE WITH EU-152M(3-EXCLUSION CHROMATOGRAPHY - A FEASIBILITY STUDY() AND SIZE)

Citation
Bj. Colston et al., KINETICS IN A EU(III)-HUMIC ACID SYSTEM BY ISOTOPIC EXCHANGE WITH EU-152M(3-EXCLUSION CHROMATOGRAPHY - A FEASIBILITY STUDY() AND SIZE), Radiochimica Acta, 78, 1997, pp. 111-115
Citations number
18
Journal title
ISSN journal
00338230
Volume
78
Year of publication
1997
Pages
111 - 115
Database
ISI
SICI code
0033-8230(1997)78:<111:KIAEAS>2.0.ZU;2-U
Abstract
The work presented illustrates the feasibility of using radiotracers w ith size exclusion chromatography (SEC) as a means of studying the kin etics of metal-ligand interactions in environmental systems. To simula te such systems a pre-equilibrated Eu(III)-humic acid model system was chosen in which Eu-152m(3+) as a radiotracer was used to study the is otopic exchange between Eu3+ and Eu(III)-humic acid complexes.