CONDUCTING POLYANILINE AS A SENSOR MATERIAL FOR THE DETECTION OF HCL VAPORS

Citation
S. Koul et al., CONDUCTING POLYANILINE AS A SENSOR MATERIAL FOR THE DETECTION OF HCL VAPORS, Indian journal of chemistry. Sect. A: Inorganic, physical, theoretical & analytical, 36(10), 1997, pp. 901-904
Citations number
26
Journal title
Indian journal of chemistry. Sect. A: Inorganic, physical, theoretical & analytical
ISSN journal
03764710 → ACNP
Volume
36
Issue
10
Year of publication
1997
Pages
901 - 904
Database
ISI
SICI code
0376-4710(1997)36:10<901:CPAASM>2.0.ZU;2-4
Abstract
The change in resistance of polyaniline on exposure to hazardous vapou rs of HCl has been utilized for the fabrication of HCl industrial sens or. The present note discusses various aspects of polyaniline based on electronic spectral study, conductivity measurements and vibrational study. These results indicate that polyaniline is an excellent materia l for sensing HCl vapours.