Js. Hsu et al., COMPARISON OF INDUCTION-MOTOR FIELD EFFICIENCY EVALUATION METHODS, IEEE transactions on industry applications, 34(1), 1998, pp. 117-125
Unlike testing motor efficiency in a laboratory, certain methods given
in IEEE Standard 112 cannot be used for motor efficiency evaluations
in the field, For example, it is difficult to load a motor in the fiel
d with a dynamometer when the motor is already coupled to driven equip
ment, The motor efficiency field evaluation faces a different environm
ent from that for which IEEE Standard 112 is chiefly written, A field
evaluation method consists of one or several basic methods, This paper
separates and compares the basic methods according to their physical
natures, Their intrusivenesses and accuracies are also discussed, This
paper is useful for field engineers to select or to establish a prope
r efficiency evaluation method by understanding the theories and error
sources of the methods.