COMPARISON OF INDUCTION-MOTOR FIELD EFFICIENCY EVALUATION METHODS

Citation
Js. Hsu et al., COMPARISON OF INDUCTION-MOTOR FIELD EFFICIENCY EVALUATION METHODS, IEEE transactions on industry applications, 34(1), 1998, pp. 117-125
Citations number
19
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
34
Issue
1
Year of publication
1998
Pages
117 - 125
Database
ISI
SICI code
0093-9994(1998)34:1<117:COIFEE>2.0.ZU;2-O
Abstract
Unlike testing motor efficiency in a laboratory, certain methods given in IEEE Standard 112 cannot be used for motor efficiency evaluations in the field, For example, it is difficult to load a motor in the fiel d with a dynamometer when the motor is already coupled to driven equip ment, The motor efficiency field evaluation faces a different environm ent from that for which IEEE Standard 112 is chiefly written, A field evaluation method consists of one or several basic methods, This paper separates and compares the basic methods according to their physical natures, Their intrusivenesses and accuracies are also discussed, This paper is useful for field engineers to select or to establish a prope r efficiency evaluation method by understanding the theories and error sources of the methods.