M. Somasundrum et al., A KINETIC-MODEL FOR THE REDUCTION OF ENZYME-GENERATED H2O2 AT A METAL-DISPERSED CONDUCTING POLYMER FILM, Journal of electroanalytical chemistry [1992], 440(1-2), 1997, pp. 259-264
This paper considers an amperometric biosensor functioning in the foll
owing manner: an oxidase enzyme reacts with its substrate to produce H
2O2, which is then reduced to water at a conducting polymer film conta
ining uniformly distributed microparticulate metal centres. The situat
ions of the enzyme in bulk solution and co-immobilised within the poly
mer film, are both considered. For both cases, approximate analytical
expressions are derived which relate the response of the sensor to exp
erimentally controllable parameters, such as substrate concentration,
film thickness, enzyme loading, etc. (C) 1997 Elsevier Science S.A.