O. Biebel et al., RADIATION MONITORING AND BEAM DUMP SYSTEM OF THE OPAL SILICON MICROVERTEX DETECTOR, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 403(2-3), 1998, pp. 351-362
The radiation monitoring and beam dump system of the OPAL silicon micr
overtex detector is described. This system was designed and implemente
d to measure the radiation dose over time scales varying from a millis
econd to a year, and to induce a fast beam dump if the radiation excee
ds a given threshold in dose and in dose rate within a very small time
interval. The system uses reverse-biased silicon diodes as sensitive
elements and good stability is achieved by AC coupling of the amplifie
rs to the sensors. (C) 1998 Published by Elsevier Science B.V. All rig
hts reserved.