CALCULATION OF PAD CROSS-TALK IN A THIN-GAP MULTIWIRE DETECTOR WITH PAD READOUT

Citation
Ai. Mincer et al., CALCULATION OF PAD CROSS-TALK IN A THIN-GAP MULTIWIRE DETECTOR WITH PAD READOUT, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 404(1), 1998, pp. 41-50
Citations number
8
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
404
Issue
1
Year of publication
1998
Pages
41 - 50
Database
ISI
SICI code
0168-9002(1998)404:1<41:COPCIA>2.0.ZU;2-1
Abstract
Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling mod el, the cross-talk is calculated as a function of chamber geometry, ca pacitances and charge integration time. Calculation results are compar ed and found to be in reasonable agreement with measurements. Suggesti ons are given for reducing cross-talk in such a chamber. (C) 1998 Else vier Science B.V. All rights reserved.