MEASUREMENT OF SYNCHRONOUS GENERATOR DATA FROM DIGITAL FAULT RECORDERS FOR TRACKING OF PARAMETERS AND FIELD DEGRADATION DETECTION

Citation
Ja. Demcko et al., MEASUREMENT OF SYNCHRONOUS GENERATOR DATA FROM DIGITAL FAULT RECORDERS FOR TRACKING OF PARAMETERS AND FIELD DEGRADATION DETECTION, Electric power systems research, 39(3), 1996, pp. 205-213
Citations number
6
Categorie Soggetti
Engineering, Eletrical & Electronic
ISSN journal
03787796
Volume
39
Issue
3
Year of publication
1996
Pages
205 - 213
Database
ISI
SICI code
0378-7796(1996)39:3<205:MOSGDF>2.0.ZU;2-N
Abstract
This paper presents a description of advanced instrumentation technolo gy developed at Arizona Public Service (APS) for on-line monitoring of large turbogenerators. These signals include three-phase generator vo ltages and currents, generator held winding voltages and currents, gen erator power angle and turbine front standard speed deviation. The dat a is collected by a 16 analog channel 10 bit digital fault recorder (D FR) for several operating conditions including steady state, transient events due to transmission line faults, etc., and staged tests. The p aper also discusses the methodology behind the use of these measured s ignals for on-line tracking of the stability parameters of a synchrono us generator. In this context, a procedure for the on-line estimation of machine parameters and turns ratios will be developed. Continuous m onitoring of the machine parameters and turns ratios in real time may then be used for incipient failure detection. (C) 1996 Elsevier Scienc e S.A.