Owing to their complex geometry, large heatsinks, such as are commonly
used in power converters and motor drive systems, may exhibit electro
magnetic resonances which enhance RF radiation characteristics within
the frequency range covered by current EU EMC regulations. Such effect
s are investigated using the finite-difference time-domain method and
compared with measurements.