COMPARISON OF TECHNETIUM 99M TETROFOSMIN AND TL-201 SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING FOR THE ASSESSMENT OF VIABLE MYOCARDIUM IN PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION

Citation
Ar. Galassi et al., COMPARISON OF TECHNETIUM 99M TETROFOSMIN AND TL-201 SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING FOR THE ASSESSMENT OF VIABLE MYOCARDIUM IN PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION, Journal of nuclear cardiology, 5(1), 1998, pp. 56-63
Citations number
34
Categorie Soggetti
Cardiac & Cardiovascular System","Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
10713581
Volume
5
Issue
1
Year of publication
1998
Pages
56 - 63
Database
ISI
SICI code
1071-3581(1998)5:1<56:COT9TA>2.0.ZU;2-8
Abstract
Background. Tetrofosmin is a new technetium 99m-labeled myocardial per fusion agent that has demonstrated favorable imaging characteristics i n recent clinical trials, However, it is not certain whether Tc-99m-te trofosmin compared with thallium 201 would underestimate myocardial vi ability in regions with left ventricular dysfunction. Methods. To this end 15 patients (mean age 52 +/- 7 years) with coronary artery diseas e and left ventricular dysfunction (ejection fraction 35% +/- 8%) docu mented on angiography underwent both quantitative rest-redistribution Tl-201 and rest Tc-99m-tetrofosmin single photon emission computed tom ography imaging.Results. Of 240 total segments on rest-redistribution Tl-201 protocol 139 (58%) segments had irreversible Tl-201 defects, Of these segments 79 (57%) had only mild to moderate reduction of Tl-201 uptake (51% to 85% of normal uptake), whereas the remaining 60 (43%) had severely reduced tracer uptake (less than or equal to 50% of norma l uptake), On Tc-99m-tetrofosmin protocol 180 (75%) segments had abnor mal Tc-99m-tetrofosmin uptake; of these segments 120 (67%) had mild to moderate reduction of Tc-99m-tetrofosmin uptake, whereas 60 (33%) had severely reduced activity. Among hypokinetic regions concordance betw een Tl-201 and Tc-99m-tetrofosmin regarding myocardial viability with a cutoff point of 50% of peak activity was obtained in 28 (90%) of 31 segments (K' = 0.80), leaving only 3 of 31 regions discordant (p = NS) , Similarly, among akinetic or dyskinetic regions concordance between the two tracers regarding myocardial viability was achieved in 54 (93% ) regions (K' = 0.75), leaving only 4 of the 58 regions discordant (p = NS). Conclusions. These data show that when the severity of uptake w as considered within abnormal segments, a similar amount of Tl-201 via ble regions were observed by Tc-99m-tetrofosmin Thus these two agents may provide comparable information about myocardial viability when qua ntitative analysis of defect severity is performed.