COMPARISON OF TECHNETIUM 99M TETROFOSMIN AND TL-201 SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING FOR THE ASSESSMENT OF VIABLE MYOCARDIUM IN PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION
Ar. Galassi et al., COMPARISON OF TECHNETIUM 99M TETROFOSMIN AND TL-201 SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING FOR THE ASSESSMENT OF VIABLE MYOCARDIUM IN PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION, Journal of nuclear cardiology, 5(1), 1998, pp. 56-63
Citations number
34
Categorie Soggetti
Cardiac & Cardiovascular System","Radiology,Nuclear Medicine & Medical Imaging
Background. Tetrofosmin is a new technetium 99m-labeled myocardial per
fusion agent that has demonstrated favorable imaging characteristics i
n recent clinical trials, However, it is not certain whether Tc-99m-te
trofosmin compared with thallium 201 would underestimate myocardial vi
ability in regions with left ventricular dysfunction. Methods. To this
end 15 patients (mean age 52 +/- 7 years) with coronary artery diseas
e and left ventricular dysfunction (ejection fraction 35% +/- 8%) docu
mented on angiography underwent both quantitative rest-redistribution
Tl-201 and rest Tc-99m-tetrofosmin single photon emission computed tom
ography imaging.Results. Of 240 total segments on rest-redistribution
Tl-201 protocol 139 (58%) segments had irreversible Tl-201 defects, Of
these segments 79 (57%) had only mild to moderate reduction of Tl-201
uptake (51% to 85% of normal uptake), whereas the remaining 60 (43%)
had severely reduced tracer uptake (less than or equal to 50% of norma
l uptake), On Tc-99m-tetrofosmin protocol 180 (75%) segments had abnor
mal Tc-99m-tetrofosmin uptake; of these segments 120 (67%) had mild to
moderate reduction of Tc-99m-tetrofosmin uptake, whereas 60 (33%) had
severely reduced activity. Among hypokinetic regions concordance betw
een Tl-201 and Tc-99m-tetrofosmin regarding myocardial viability with
a cutoff point of 50% of peak activity was obtained in 28 (90%) of 31
segments (K' = 0.80), leaving only 3 of 31 regions discordant (p = NS)
, Similarly, among akinetic or dyskinetic regions concordance between
the two tracers regarding myocardial viability was achieved in 54 (93%
) regions (K' = 0.75), leaving only 4 of the 58 regions discordant (p
= NS). Conclusions. These data show that when the severity of uptake w
as considered within abnormal segments, a similar amount of Tl-201 via
ble regions were observed by Tc-99m-tetrofosmin Thus these two agents
may provide comparable information about myocardial viability when qua
ntitative analysis of defect severity is performed.