COLLATERAL FLOW DETECTED BY A DOPPLER GUIDE-WIRE IN A CASE OF VASOSPASTIC ANGINA

Citation
N. Tasaki et al., COLLATERAL FLOW DETECTED BY A DOPPLER GUIDE-WIRE IN A CASE OF VASOSPASTIC ANGINA, Internal medicine, 37(1), 1998, pp. 65-68
Citations number
7
Categorie Soggetti
Medicine, General & Internal
Journal title
ISSN journal
09182918
Volume
37
Issue
1
Year of publication
1998
Pages
65 - 68
Database
ISI
SICI code
0918-2918(1998)37:1<65:CFDBAD>2.0.ZU;2-#
Abstract
We could detect recruitable backward collateral how in systole and dia stole by using a Doppler guide wire during coronary artery spasm in a 42-year-old female among 20 patients with documented variant angina, T he electrocardiogram (EGG) showed no ST-segment deviation, although sh e had chest pain and her coronary angiography showed a totally occlude d right coronary artery. After administration of isosorbide dinitrate (ISDN) the collateral flow disappeared and the flow pattern recovered to normal, The good collateral flow pattern in patient with totally oc cluded coronary artery due to spasm was indicated to relieve myocardia l ischemia, even when the patient felt chest pain.