COLOR DOPPLER ENERGY - DETECTION OF HYPOPERFUSED AREAS IN RENAL-TRANSPLANTS

Citation
A. Nilsson et al., COLOR DOPPLER ENERGY - DETECTION OF HYPOPERFUSED AREAS IN RENAL-TRANSPLANTS, Journal of ultrasound in medicine, 17(3), 1998, pp. 153-155
Citations number
9
Categorie Soggetti
Acoustics,"Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
02784297
Volume
17
Issue
3
Year of publication
1998
Pages
153 - 155
Database
ISI
SICI code
0278-4297(1998)17:3<153:CDE-DO>2.0.ZU;2-#
Abstract
The aim of this study was to determine if an area of decreased color o n color Doppler energy scans in a transplanted kidney could be related to significant pathologic conditions. Three hundred and ninety-eight scans in 150 patients were thus evaluated prospectively, and 12 such a reas were found and correlated to B-mode, spectral, and color Doppler sonography as well as clinical and laboratory findings. A cause for th e hypoperfused area was found in all cases; causes included two cases of focal infection, four arteriovenous fistulas, one kinking of an art ery, and five perioperatively severed accessory arteries. We conclude that a color Doppler energy evaluation of perfusion differences can be used to detect pathologic lesions in a transplanted kidney.