USE OF PHOTODIODE IN MICRODOSIMETRY AND EVALUATION OF EFFECTIVE QUALITY FACTOR

Citation
A. Kadachi et al., USE OF PHOTODIODE IN MICRODOSIMETRY AND EVALUATION OF EFFECTIVE QUALITY FACTOR, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 404(2-3), 1998, pp. 400-406
Citations number
15
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
404
Issue
2-3
Year of publication
1998
Pages
400 - 406
Database
ISI
SICI code
0168-9002(1998)404:2-3<400:UOPIMA>2.0.ZU;2-R
Abstract
A silicon photodiode in conjunction with a charged particle radiator p laced in front of the sensitive layer was employed to construct a micr odosimetric detector. Silicon photodiodes of different types (PN, PIN and PNN) and of different sensitive layers (1, 3, 5 and 8 mu m) were u sed to obtain the pulse height spectrum for an Am-Be neutron source. T he data were analysed to determine the microdosimetric spectra and the effective quality factor (Q) over bar was estimated. Two types of cor rections were needed for the estimate of (Q) over bar. One is related to the weighting function Q(L) and the other deals with the fractional relative dose d(L). The results were compared with those obtained wit h Tissue Equivalent Proportional Counter (TEPC) of 1 mu m simulated di ameter and were found to be in good agreement. (C) 1998 Elsevier Scien ce B.V. All rights reserved.