K. Budak et al., DEHISCENCE OF A RADIAL KERATOTOMY INCISION DURING CLEAR CORNEAL CATARACT-SURGERY, Journal of cataract and refractive surgery, 24(2), 1998, pp. 278-280
We report a case of dehiscence of a radial keratotomy (RK) incision ca
used by clear corneal cataract surgery. The patient had had eight-inci
sion RK in both eyes 9 months previously with enhancement surgery in t
he left eye 1 month later. Cataract surgery through a clear corneal in
cision was performed in the right eye and 1 month later, in the left.
Surgery in the right eye was uneventful. However, during surgery in th
e left eye, dehiscence of one radial incision occurred. The wound dehi
scence was closed with interrupted sutures, and the patient achieved 2
0/20 uncorrected visual acuity 1 week after surgery.