DEHISCENCE OF A RADIAL KERATOTOMY INCISION DURING CLEAR CORNEAL CATARACT-SURGERY

Citation
K. Budak et al., DEHISCENCE OF A RADIAL KERATOTOMY INCISION DURING CLEAR CORNEAL CATARACT-SURGERY, Journal of cataract and refractive surgery, 24(2), 1998, pp. 278-280
Citations number
26
Categorie Soggetti
Surgery,Ophthalmology
ISSN journal
08863350
Volume
24
Issue
2
Year of publication
1998
Pages
278 - 280
Database
ISI
SICI code
0886-3350(1998)24:2<278:DOARKI>2.0.ZU;2-4
Abstract
We report a case of dehiscence of a radial keratotomy (RK) incision ca used by clear corneal cataract surgery. The patient had had eight-inci sion RK in both eyes 9 months previously with enhancement surgery in t he left eye 1 month later. Cataract surgery through a clear corneal in cision was performed in the right eye and 1 month later, in the left. Surgery in the right eye was uneventful. However, during surgery in th e left eye, dehiscence of one radial incision occurred. The wound dehi scence was closed with interrupted sutures, and the patient achieved 2 0/20 uncorrected visual acuity 1 week after surgery.